Join Us Close. Are you an Engineering professional? Join Eng-Tips Forums! Join Us! By joining you are opting in to receive e-mail. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Related Projects. Can anyone tell me what an ISO 7 R thread is? I'm thinking that it's just a different name for a BSPT. But I need to be sure. Thanks in advance. If you want to promote your products or services in the Engineering ToolBox - please use Google Adwords.

Make Shortcut to Home Screen? Sponsored Links. Characteristics of ISO 7 tapered Withworth threads are tapered thread 1 o 47' truncation of roots and crests are rounded 55 o thread angle pitch is measured in threads per inch Note! For full table with Thread Tolerances - rotate the screen! Privacy We don't collect information from our users. Citation This page can be cited as Engineering ToolBox, Modify access date. Scientific Online Calculator. In addition, an ISO 5 or class clean room needs to use unidirectional air flow.

Unidirectional air flow cleanrooms use much more air than non-directional air flow cleanrooms. High efficiency filters are installed across the entire ceiling. The filtered air sweeps down the room in a unidirectional way, at a velocity generally between 0. Cleanrooms using unidirectional air flow are more expensive than non-unidirectional ones, but can comply with more stringent classifications, such as ISO 5 or lower.

ISO 5 Nanofabrication cleanroom facility. As stated before, clean rooms are classified by how clean the air is, according to the number of particles and size of particles per volume of air.

Some classifications do not require certain particle sizes to be tested because the respective concentrations are too low or too high to be tested, but they should not be zero.

For ISO 7, particles smaller than 0. Air cleanliness is achieved by passing the air through HEPA filters using flow principles such as laminar flow. The more often the air passes through the HEPA filters, the fewer particles are left in the room air. The volume of air filtered in one hour divided by the volume of the room gives the number of air changes per hour.

The above-suggested air changes per hour are only a design rule of thumb. They should be computed by an HVAC clean room expert, as many aspects must be taken into consideration, such as the size of the room, the number of people in the room, the equipment in the room, the processes involved, the heat gain, etc. Contact our experts to discuss your project. Please note that this information is only provided for educational purposes.

The definitions in this article are oversimplified in order to assist with understanding. This article will not help you decide which clean room classification you must reach. If help is needed in this respect, seek the advice of an expert in your industry pharmaceutical, medical devices, sterile compounding, electronics, etc. We can Design-Build-Install and Commission your cleanroom or we can partner with other professionals that your are currently working with!